Circuit breaker size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 8 A N-release 104 A screw terminal Standard switching capacity | ||
Product brand name | SIRIUS | |
Product designation | Circuit breaker | |
Design of the product | For system protection according to UL 489/CSA C22.2 No. 5 | |
Product type designation | 3RV2 | |
General technical data | ||
Size of the circuit-breaker | S00 | |
Product extension auxiliary switch | Yes | |
Power loss [W] for rated value of the current | ||
● at AC in hot operating state | 9.25 W | |
● at AC in hot operating state per pole | 3.1 W | |
Insulation voltage with degree of pollution 3 at AC rated value | 690 V | |
Surge voltage resistance rated value | 6 kV | |
Shock resistance according to IEC 60068-2-27 | 25 g / 11 ms (rectangular impulse and sine pulse) | |
Mechanical service life (operating cycles) | ||
● of the main contacts typical | 100 000 | |
● of auxiliary contacts typical | 100 000 | |
Electrical endurance (operating cycles) typical | 100 000 | |
Reference code according to IEC 81346-2 | Q | |
Substance Prohibitance (Date) | 10/01/2009 | |
SVHC substance name | Lead – 7439-92-1 | |
Ambient conditions | ||
Installation altitude at height above sea level maximum | 2 000 m | |
Ambient temperature | ||
● during operation | -20 … +60 °C | |
● during storage | -50 … +80 °C | |
● during transport | -50 … +80 °C | |
Relative humidity during operation | 10 … 95 % | |
Main circuit | ||
Number of poles for main current circuit | 3 | |
Operating voltage | ||
● rated value | 20 … 690 V | |
● at AC-3 rated value maximum | 690 V | |
● at AC-3e rated value maximum | 690 V | |
Operating frequency rated value | 50 … 60 Hz | |
Operational current rated value | 8 A | |
Operational current | ||
● at AC-3 at 400 V rated value | 8 A | |
● at AC-3e at 400 V rated value | 8 A | |
Operating power | ||
● at AC-3 | ||
— at 230 V rated value | 1.5 kW | |
— at 400 V rated value | 3 kW | |
— at 500 V rated value | 4 kW | |
— at 690 V rated value | 5.5 kW | |
● at AC-3e | ||
— at 230 V rated value | 1.5 kW | |
— at 400 V rated value | 3 kW | |
— at 500 V rated value | 4 kW | |
— at 690 V rated value | 5.5 kW | |
Operating frequency | ||
● at AC-3 maximum | 15 1/h | |
● at AC-3e maximum | 15 1/h | |
Protective and monitoring functions | ||
Product function | ||
● ground fault detection | No | |
● phase failure detection | No | |
Design of the overload release | Thermal | |
Maximum short-circuit current breaking capacity (Icu) | ||
● at AC at 240 V rated value | 100 kA | |
● at AC at 400 V rated value | 100 kA | |
● at AC at 500 V rated value | 42 kA | |
● at AC at 690 V rated value | 6 kA | |
● at 480 AC Y/277 V according to UL 489 rated value | 65 kA | |
Operating short-circuit current breaking capacity (Ics) at AC | ||
● at 240 V rated value | 100 kA | |
● at 400 V rated value | 100 kA | |
● at 500 V rated value | 42 kA | |
● at 690 V rated value | 4 kA | |
Response value current of instantaneous short-circuit trip unit | 104 A | |
Short-circuit protection | ||
Product function short circuit protection | Yes | |
Design of the short-circuit trip | Magnetic | |
Design of the fuse link for IT network for short-circuit protection of the main circuit | ||
● at 400 V | GG 50 A | |
● at 500 V | GG 40 A | |
● at 690 V | GG 35 A | |
Installation/ mounting/ dimensions | ||
Mounting position | Any | |
Fastening method | Screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 | |
Height | 144 mm | |
Width | 45 mm | |
Depth | 97 mm | |
Required spacing | ||
● for grounded parts at 400 V | ||
— downwards | 30 mm | |
— upwards | 30 mm | |
— at the side | 30 mm | |
● for live parts at 400 V | ||
— downwards | 30 mm | |
— upwards | 30 mm | |
— at the side | 30 mm | |
● for grounded parts at 500 V | ||
— downwards | 30 mm | |
— upwards | 30 mm | |
— at the side | 30 mm | |
● for live parts at 500 V | ||
— downwards | 30 mm | |
— upwards | 30 mm | |
— at the side | 30 mm | |
● for grounded parts at 690 V | ||
— downwards | 70 mm | |
— upwards | 70 mm | |
— backwards | 0 mm | |
— at the side | 30 mm | |
— forwards | 0 mm | |
● for live parts at 690 V | ||
— downwards | 70 mm | |
— upwards | 70 mm | |
— backwards | 0 mm | |
— at the side | 30 mm | |
— forwards | 0 mm | |
Connections/ Terminals | ||
Type of electrical connection | ||
● for main current circuit | Screw-type terminals | |
Arrangement of electrical connectors for main current circuit | Top and bottom | |
Type of connectable conductor cross-sections | ||
● for main contacts | ||
— solid or stranded | 1 … 10 mm², max. 2x 10 mm² | |
— finely stranded with core end processing | 1 … 16 mm², max. 6 + 16 mm² | |
● for AWG cables for main contacts | 2x (14 … 10) | |
Tightening torque | ||
● for main contacts with screw-type terminals | 2.5 … 3 N·m | |
Design of screwdriver shaft | Diameter 5 to 6 mm | |
Size of the screwdriver tip | Pozidriv size 2 | |
Design of the thread of the connection screw | ||
● for main contacts | M4 | |
Safety related data | ||
Product function suitable for safety function | Yes | |
Suitability for use | ||
● safety-related switching on | No | |
● safety-related switching OFF | Yes | |
Service life maximum | 10 a | |
Test wear-related service life necessary | Yes | |
Proportion of dangerous failures | ||
● with low demand rate according to SN 31920 | 40 % | |
● with high demand rate according to SN 31920 | 50 % | |
B10 value with high demand rate according to SN 31920 | 5 000 | |
Failure rate [FIT] with low demand rate according to SN 31920 | 50 FIT | |
ISO 13849 | ||
Device type according to ISO 13849-1 | 3 | |
Overdimensioning according to ISO 13849-2 necessary | Yes | |
IEC 61508 | ||
Safety device type according to IEC 61508-2 | Type A | |
T1 value | ||
● for proof test interval or service life according to IEC 61508 | 10 a | |
Electrical Safety | ||
Protection class IP on the front according to IEC 60529 | IP20 | |
Touch protection on the front according to IEC 60529 | Finger-safe, for vertical contact from the front | |
Display |
Xem thêm tại Datasheet
Để được tư vấn trực tiếp, quý khách vui lòng liên hệ với chúng tôi theo thông tin sau:
➢ Tư vấn bán hàng: 0904 777 528 / 0799 15 95 95 (call/zalo)
➢ Email: info@mtee.vn
TRỤ SỞ CHÍNH
Địa chỉ: 30/17A Đường Tam Bình, KP8, Phường Hiệp Bình Chánh, Thành Phố Thủ Đức, Thành phố Hồ Chí Minh
MST: 0314561574
Cảm ơn quý khách đã truy cập vào website MTEE.VN. Kính chúc quý khách nhận được những thông tin hữu ích và có những trải nghiệm tuyệt vời trên trang.
Đánh giá 3RV2711-1HD10 – Bộ ngắt mạch bảo vệ motor