Circuit breaker size S00 for motor protection, Class 10 A-release 3.5…5 A Short-circuit release 65 A spring-type terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC | ||
Product brand name | SIRIUS | |
Product designation | Circuit breaker | |
Design of the product | For motor protection | |
Product type designation | 3RV2 | |
Substance Prohibitance (Date) | 10/01/2009 | |
SVHC substance name | Lead – 7439-92-1 | |
Main circuit | ||
Operating voltage | ||
● rated value | 20 … 690 V | |
● at AC-3 rated value maximum | 690 V | |
● at AC-3e rated value maximum | 690 V | |
Operational current rated value | 5 A | |
Operational current | ||
● at AC-3 at 400 V rated value | 5 A | |
● at AC-3e at 400 V rated value | 5 A | |
Operating power | ||
● at AC-3 | ||
— at 230 V rated value | 1.1 kW | |
— at 400 V rated value | 1.5 kW | |
— at 500 V rated value | 2.2 kW | |
— at 690 V rated value | 4 kW | |
● at AC-3e | ||
— at 230 V rated value | 1.1 kW | |
— at 400 V rated value | 1.5 kW | |
— at 500 V rated value | 2.2 kW | |
— at 690 V rated value | 4 kW | |
Operating frequency | ||
● at AC-3 maximum | 15 1/h | |
● at AC-3e maximum | 15 1/h | |
Protective and monitoring functions | ||
Trip class | CLASS 10 | |
Maximum short-circuit current breaking capacity (Icu) | ||
● at AC at 240 V rated value | 100 kA | |
● at AC at 400 V rated value | 100 kA | |
● at AC at 500 V rated value | 100 kA | |
● at AC at 690 V rated value | 6 kA | |
Operating short-circuit current breaking capacity (Ics) at AC | ||
● at 240 V rated value | 100 kA | |
● at 400 V rated value | 100 kA | |
● at 500 V rated value | 100 kA | |
● at 690 V rated value | 4 kA | |
Response value current of instantaneous short-circuit trip unit | 65 A | |
Safety related data | ||
Product function suitable for safety function | Yes | |
Suitability for use | ||
● safety-related switching on | No | |
● safety-related switching OFF | Yes | |
Service life maximum | 10 a | |
Test wear-related service life necessary | Yes | |
Proportion of dangerous failures | ||
● with low demand rate according to SN 31920 | 40 % | |
● with high demand rate according to SN 31920 | 50 % | |
B10 value with high demand rate according to SN 31920 | 5 000 | |
Failure rate [FIT] with low demand rate according to SN 31920 | 50 FIT | |
ISO 13849 | ||
Device type according to ISO 13849-1 | 3 | |
Overdimensioning according to ISO 13849-2 necessary | Yes | |
IEC 61508 | ||
Safety device type according to IEC 61508-2 | Type A | |
Electrical Safety | ||
Protection class IP on the front according to IEC 60529 | IP20 | |
Touch protection on the front according to IEC 60529 | Finger-safe, for vertical contact from the front | |
Approvals Certificates |
Xem thêm tại Datasheet
Để được tư vấn trực tiếp, quý khách vui lòng liên hệ với chúng tôi theo thông tin sau:
➢ Tư vấn bán hàng: 0904 777 528 / 0799 15 95 95 (call/zalo)
➢ Email: info@mtee.vn
TRỤ SỞ CHÍNH
Địa chỉ: 30/17A Đường Tam Bình, KP8, Phường Hiệp Bình Chánh, Thành Phố Thủ Đức, Thành phố Hồ Chí Minh
MST: 0314561574
Cảm ơn quý khách đã truy cập vào website MTEE.VN. Kính chúc quý khách nhận được những thông tin hữu ích và có những trải nghiệm tuyệt vời trên trang.
Đánh giá 3RV2011-1FA25-Z X95 – Bộ ngắt mạch bảo vệ motor